TY - JOUR
T1 - Rapid lung ventilation MRI using parahydrogen-induced polarization of propane gas
AU - Chowdhury, Md Raduanul H.
AU - Oladun, Clementinah
AU - Ariyasingha, Nuwandi M.
AU - Samoilenko, Anna
AU - Bawardi, Tarek
AU - Burueva, Dudari B.
AU - Salnikov, Oleg G.
AU - Kovtunova, Larisa M.
AU - Bukhtiyarov, Valerii I.
AU - Shi, Zhongjie
AU - Luo, Kehuan
AU - Tan, Sidhartha
AU - Gelovani, Juri G.
AU - Koptyug, Igor V.
AU - Goodson, Boyd M.
AU - Chekmenev, Eduard Y.
N1 - Publisher Copyright:
© 2024 The Royal Society of Chemistry.
PY - 2024/11/12
Y1 - 2024/11/12
N2 - Proton-hyperpolarized contrast agents are attractive because they can be imaged on virtually any clinical MRI scanner, which is typically equipped to scan only protons rather than heteronuclei (i.e., anything besides protons, e.g., 13C, 15N, 129Xe, 23Na, etc.). Even though the lifetime of the proton spin hyperpolarization is only a few seconds, it is sufficient for inhalation and scanning of proton-hyperpolarized gas media. We demonstrate the utility of producing hyperpolarized propane gas via heterogeneous parahydrogen-induced polarization for the purpose of ventilation imaging in an excised rabbit lung model. The magnetization of protons in hyperpolarized propane gas is similar to that of tissue water protons, making it possible to rapidly perform lung ventilation imaging with a 0.35 T clinical MRI scanner. Here, we demonstrate the feasibility of rapid (2 s) lung ventilation MRI in excised rabbit lungs using hyperpolarized propane gas with a 1 × 1 mm2 pixel size using a 50 mm slice thickness, and a 1.7 × 1.7 mm2 pixel size using a 9 mm slice thickness.
AB - Proton-hyperpolarized contrast agents are attractive because they can be imaged on virtually any clinical MRI scanner, which is typically equipped to scan only protons rather than heteronuclei (i.e., anything besides protons, e.g., 13C, 15N, 129Xe, 23Na, etc.). Even though the lifetime of the proton spin hyperpolarization is only a few seconds, it is sufficient for inhalation and scanning of proton-hyperpolarized gas media. We demonstrate the utility of producing hyperpolarized propane gas via heterogeneous parahydrogen-induced polarization for the purpose of ventilation imaging in an excised rabbit lung model. The magnetization of protons in hyperpolarized propane gas is similar to that of tissue water protons, making it possible to rapidly perform lung ventilation imaging with a 0.35 T clinical MRI scanner. Here, we demonstrate the feasibility of rapid (2 s) lung ventilation MRI in excised rabbit lungs using hyperpolarized propane gas with a 1 × 1 mm2 pixel size using a 50 mm slice thickness, and a 1.7 × 1.7 mm2 pixel size using a 9 mm slice thickness.
UR - https://www.scopus.com/pages/publications/85208809841
U2 - 10.1039/d4an01029a
DO - 10.1039/d4an01029a
M3 - Article
C2 - 39530397
AN - SCOPUS:85208809841
SN - 0003-2654
VL - 149
SP - 5832
EP - 5842
JO - Analyst
JF - Analyst
IS - 24
ER -