Skip to main navigation Skip to search Skip to main content

Outcomes of a Newly Established Electromagnetic Navigation Bronchoscopy Service in the Middle East

Research output: Contribution to journal › Article › peer-review

1 Scopus citations

Abstract

Aims: Electromagnetic Navigation Bronchoscopy (EMNB) is a useful tool for the bronchoscopist to target peripheral pulmonary lesions. It has a well-established efficacy and safety profile; however, there are no studies describing its utility in a Middle Eastern population. In this paper, we describe the efficacy and safety outcomes of a newly established EMNB service. Background: The diagnosis of peripheral pulmonary lesions presents a significant challenge to the bronchoscopist, especially in the era of increased thoracic imaging with computerized tomography (CT) scans. EMNB is a relatively novel technique that utilizes an image-guided localization system akin to Global Positioning Satellite (GPS) technology, offering the bronchoscopist an accurate navigational pathway to sample peripheral pulmonary targets. Objective: We present our initial experience of performing EMNB and report our diagnostic and safety outcomes with EMN bronchoscopy. Methods: We conducted a retrospective review of the medical notes of all patients booked for EMNB from May 2015 to December 2019 at our tertiary care center using the electronic medical record system. Results and Discussion: Fifty-five patients were scheduled for EMNB, and 47 patients (24 males, 23 females) had EMNB-guided sampling between May 2015 and December 2019. The median age of the patients was 61 years (IQR 49.5-74.3). A bronchus sign was present on the CT chest in 29 (61.7%) cases. Thirty-one (66%) patients had positive EMNB guided samples. There was a weak correlation between the lesion size and the positive EMNB guided sampling (r: 0.34). Twenty-one of 29 (72%) patients with positive bronchus signs had positive EMNB guided samples, compared to 10/18 (56%) patients without bronchus signs; however, the difference was not statistically significant (p-value 0.335). When the presence or absence of rapid onsite examination of cytopathological specimens (ROSE) was compared during the procedure, a trend favoring the presence of ROSE could be seen, but this was statistically non-significant (p-value 0.078). In this series, one patient with pre-existing triple vessel coronary artery disease developed an inferior wall ST-segment elevation myocardial infarction (STEMI), likely secondary to spasm. This patient recovered completely and was discharged from the hospital. Conclusion: This study demonstrates that EMNB can be safely performed in a Middle Eastern population with results similar to those reported in major international studies. The highest diagnostic yield was in patients with a bronchus sign on a CT scan, and combining EMNB with ROSE can increase the chances of having a positive diagnostic bronchoscopy. However, patients and physicians need to be aware of the need to follow up with the patients with negative biopsies to ensure that false negatives are not missed.

Original languageEnglish
Article numbere187430642204210
JournalOpen Respiratory Medicine Journal
Volume16
DOIs
StatePublished - 2022

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Keywords

  • CT
  • Electromagnetic navigation bronchoscopy
  • Fluoroscopy
  • Peripheral pulmonary lesions
  • Radial electrobronchial ultrasound
  • Rapid onsite cytologic examination

Fingerprint

Dive into the research topics of 'Outcomes of a Newly Established Electromagnetic Navigation Bronchoscopy Service in the Middle East'. Together they form a unique fingerprint.

Cite this