A 25-year-old man presented with decreased vision in both eyes, approximately 4 years following bilateral bright ocular cosmetic iris implantation. On examination, he was found to have bilateral elevated intraocular pressures, anterior chamber cells and flare, chronic peripheral anterior synechiae and significantly reduced endothelial cell counts. Ultrasound biomicroscopy demonstrated compression of the peripheral iris, resulting in synechial angle closure in both eyes. Surgical removal of the implants was performed without additional complication. On removal, bilateral iris atrophy was evident with non-reacting pupils and permanent mydriasis. Optical coherence tomography angiography showed a reduction in iris vasculature density that is more pronounced in the area of the iris atrophic defects. This case suggests that cosmetic iris implants may compress iris vasculature, resulting in decreased iris perfusion resulting in atrophic mydriasis and iris defects. This is a potential novel mechanism for complications in eyes with cosmetic iris implants.

Original languageEnglish
Article numbere239308
JournalBMJ Case Reports
Volume14
Issue number2
DOIs
StatePublished - 4 Feb 2021

Keywords

  • anterior chamber
  • glaucoma
  • iris

Fingerprint

Dive into the research topics of 'Novel mechanism of decreased iris vasculature density after cosmetic iris implants'. Together they form a unique fingerprint.

Cite this