Skip to main navigation Skip to search Skip to main content

Integrating of electrocoagulation process with submerged membrane bioreactor for wastewater treatment under low voltage gradients

  • Khalid Bani-Melhem
  • , Maria Elektorowicz
  • , Muhammad Tawalbeh
  • , Abeer Al Bsoul
  • , Ahmed El Gendy
  • , Hesam Kamyab
  • , Mohammad Yusuf
  • Center for Advanced Materials, Qatar University
  • Concordia University
  • Al-Balqa Applied University
  • The American University in Cairo
  • Universidad Tecnológica Equinoccial
  • Saveetha Institute of Medical and Technical Sciences (Deemed to be University)
  • Universiti Teknologi Malaysia
  • Universiti Teknologi Petronas

Research output: Contribution to journal › Article › peer-review

25 Scopus citations

Abstract

Treating and reusing wastewater has become an essential aspect of water management worldwide. However, the increase in emerging pollutants such as polycyclic aromatic hydrocarbons (PAHs), which are presented in wastewater from various sources like industry, roads, and household waste, makes their removal difficult due to their low concentration, stability, and ability to combine with other organic substances. Therefore, treating a low load of wastewater is an attractive option. The study aimed to address membrane fouling in the submerged membrane bioreactor (SMBR) used for wastewater treatment. An aluminum electrocoagulation (EC) device was combined with SMBR as a pre-treatment to reduce fouling. The EC-SMBR process was compared with a conventional SMBR without EC, fed with real grey water. To prevent impeding biological growth, low voltage gradients were utilized in the EC deviceThe comparison was conducted over 60 days with constant transmembrane pressure and infinite solid retention time (SRT). In phase I, when the EC device was operated at a low voltage gradient (0.64 V/cm), no significant improvement in the pollutants removal was observed in terms of color, turbidity, and chemical oxygen demand (COD). Nevertheless, during phase II, a voltage gradient of 1.26 V/cm achieved up to 100%, 99.7%, 92%, 94.1%, and 96.5% removals in the EC-SMBR process in comparison with 95.1%, 95.4%, 85%, 91.7% and 74.2% removals in the SMBR process for turbidity, color, COD, ammonia nitrogen (NH3–N), total phosphorus (TP), respectively. SMBR showed better anionic surfactant (AS) removal than EC-SMBR. A voltage gradient of 0.64 V/cm in the EC unit significantly reduced fouling by 23.7%, while 1.26 V/cm showed inconsistent results. Accumulation of Al ions negatively affected membrane performance. Low voltage gradients in EC can control SMBR fouling if Al concentration is controlled. Future research should investigate EC-SMBR with constant membrane flux for large-scale applications, considering energy consumption and operating costs.

Original languageEnglish
Article number139693
JournalChemosphere
Volume339
DOIs
StatePublished - Oct 2023

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 6 - Clean Water and Sanitation
    SDG 6 Clean Water and Sanitation
  2. SDG 9 - Industry, Innovation, and Infrastructure
    SDG 9 Industry, Innovation, and Infrastructure

Keywords

  • Electrocoagulation
  • Grey water
  • Membrane fouling
  • PAHs
  • Submerged membrane bioreactor

Fingerprint

Dive into the research topics of 'Integrating of electrocoagulation process with submerged membrane bioreactor for wastewater treatment under low voltage gradients'. Together they form a unique fingerprint.

Cite this