TY - JOUR
T1 - Guidance for reporting artificial intelligence technology evaluations for ultrasound scanning in regional anaesthesia (GRAITE-USRA)
T2 - an international multidisciplinary consensus reporting framework
AU - the GRAITE-USRA Working Group
AU - Zhang, Xiaoxi
AU - Ferry, Jenny
AU - Hewson, David W.
AU - Collins, Gary S.
AU - Wiles, Matthew D.
AU - Zhao, Yi
AU - Martindale, Alexander P.L.
AU - Tomaschek, Michael
AU - Bowness, James S.
AU - Dixon, Adam J.
AU - Hadzic, Admir
AU - Karthikesalingam, Alan
AU - Macfarlane, Alan
AU - Novak, Alex
AU - Sia, Alex T.
AU - Chuan, Alwin
AU - Pawa, Amit
AU - Samir, Anthony E.
AU - Nagdev, Arun
AU - Balakrishnan, Ashokka
AU - Thottungal, Athmaja
AU - Fox, Benjamin
AU - Bellew, Boyne
AU - Shiran, Carmit
AU - Lobo, Clara
AU - McCartney, Colin J.L.
AU - Loomis, Craig
AU - Kamming, Damon
AU - Perry, Daniel
AU - Aus, Ealdei
AU - Mariano, Edward R.
AU - Moka, Eleni
AU - Smistad, Erik
AU - Retief, Francois
AU - Collins, Gary
AU - McCaulley, Gwendolynn
AU - Richardson, Hannah
AU - Hemmings, Hugh
AU - Muse, Iyabo O.
AU - Ferry, Jenny
AU - Weller, Jennifer M.
AU - Pantoja, Juan Pablo Miranda
AU - El-Boghdadly, Kariem
AU - Misra, Lopa
AU - Van de Velde, Marc
AU - Benson, Martin
AU - Davies, Matthew
AU - Wiles, Matthew
AU - Byrne, Melissa L.
AU - Mostafa Mohamed, Mohamed
N1 - Publisher Copyright:
© 2025 The Author(s). Anaesthesia published by John Wiley & Sons Ltd on behalf of Association of Anaesthetists.
PY - 2025/12
Y1 - 2025/12
N2 - Introduction: The application of artificial intelligence to enhance the clinical practice of ultrasound-guided regional anaesthesia is of increasing interest to clinicians, researchers and industry. The lack of standardised reporting for studies in this field hinders the comparability, reproducibility and integration of findings. We aimed to develop a consensus-based reporting guideline for research evaluating artificial intelligence applications for ultrasound scanning in regional anaesthesia. Methods: We followed methodology recommended by the EQUATOR Network for the development of reporting guidelines. Review of published literature and expert consultation generated a preliminary list of candidate reporting items. An international, multidisciplinary, modified Delphi process was then undertaken, involving experts from clinical practice, academia and industry. Two rounds of expert consultation were conducted, in which participants evaluated each item for inclusion in a final reporting guideline, followed by an online discussion. Results: A total of 67 experts participated in the first Delphi round, 63 in the second round and 25 in the roundtable consensus meeting. The GRAITE-USRA reporting guideline comprises 40 items addressing key aspects of reporting in artificial intelligence research for ultrasound scanning in regional anaesthesia. Specific items include ultrasound acquisition protocols and operator expertise, which are not covered in existing artificial intelligence reporting guidelines. Discussion: The GRAITE-USRA reporting guideline provides a minimum set of recommendations for artificial intelligence-related research for ultrasound scanning in regional anaesthesia. Its adoption will promote consistent reporting standards, enhance transparency, improve study reproducibility and ultimately support the effective integration of evidence into clinical practice.
AB - Introduction: The application of artificial intelligence to enhance the clinical practice of ultrasound-guided regional anaesthesia is of increasing interest to clinicians, researchers and industry. The lack of standardised reporting for studies in this field hinders the comparability, reproducibility and integration of findings. We aimed to develop a consensus-based reporting guideline for research evaluating artificial intelligence applications for ultrasound scanning in regional anaesthesia. Methods: We followed methodology recommended by the EQUATOR Network for the development of reporting guidelines. Review of published literature and expert consultation generated a preliminary list of candidate reporting items. An international, multidisciplinary, modified Delphi process was then undertaken, involving experts from clinical practice, academia and industry. Two rounds of expert consultation were conducted, in which participants evaluated each item for inclusion in a final reporting guideline, followed by an online discussion. Results: A total of 67 experts participated in the first Delphi round, 63 in the second round and 25 in the roundtable consensus meeting. The GRAITE-USRA reporting guideline comprises 40 items addressing key aspects of reporting in artificial intelligence research for ultrasound scanning in regional anaesthesia. Specific items include ultrasound acquisition protocols and operator expertise, which are not covered in existing artificial intelligence reporting guidelines. Discussion: The GRAITE-USRA reporting guideline provides a minimum set of recommendations for artificial intelligence-related research for ultrasound scanning in regional anaesthesia. Its adoption will promote consistent reporting standards, enhance transparency, improve study reproducibility and ultimately support the effective integration of evidence into clinical practice.
KW - evaluation
KW - regional anaesthesia
KW - reporting
KW - ultrasound artificial intelligence
UR - https://www.scopus.com/pages/publications/105018100359
U2 - 10.1111/anae.16733
DO - 10.1111/anae.16733
M3 - Article
C2 - 40963489
AN - SCOPUS:105018100359
SN - 0003-2409
VL - 80
SP - 1528
EP - 1539
JO - Anaesthesia
JF - Anaesthesia
IS - 12
ER -