Conformity Evaluation of Afinion 2 Analyzer Maintainability: Compliance Practicality for Philippine National Standard PNS ISO 15189:2013 Accreditation

  • Geraldine B. Dayrit
  • , Dennis Mok
  • , Rana Nabulsi
  • , Naira Eloyan
  • , Sharfuddin Chowdhury
  • , Arisina Chung Yee Ma
  • University of the Philippines
  • Medical Management Consulting
  • Scientific Center of Drug and Medical Technology Expertise
  • AMAS
  • King Saud Medical City
  • Nottingham University Hospitals NHS Trust

Research output: Contribution to journal › Article › peer-review

Abstract

Objectives. The implementation of Philippine National Standard PNS ISO 15189:2013 to support the medical laboratory to produce competent results is a recognised challenge. It is apparent that the approach of ensuring the equipment availability can be specifically optimised. No known research has focused on exploring on the conduct of conformity evaluation of Afinion 2 Analyzer maintainability for the PNS ISO 15189:2013 accredited medical laboratory. The aim of the current study was to develop a practical tool for the medical laboratory to support the internal audit process by determining the compliance status of Afinion 2 Analyzer maintainability. Methods. The relevant conformance requirements in Clauses 4 (Management requirements) and 5 (Technical requirements) of PNS ISO 15189:2013, manufacturer requirements and specific requirements for accreditation from 70/101 (69%) accreditation bodies in 80/249 (32%) countries were identified as specific audit criteria for Afinion 2 Analyzer conformity evaluation checklists for the maintenance and reference equipment. Results. This study identified a total of 44/1515 (2.9%) conformance requirements and 33/1515 (2.2%) conformance requirements was associated with the hardware and software component of Afinion 2 Analyzer, respectively in Clauses 4 and 5 of PNS ISO 15189:2013. In addition, manufacturer requirements (n = 5) were identified relating to preventive maintenance. Further, specific requirements for accreditation for maintenance of reference equipment were identified and selected from 13/75 (17%) accreditation bodies in 26/90 (29%) countries; together these requirements were used to develop conformity evaluation of Afinion 2 Analyzer checklists (n = 3) and an interpretation checklist. Conclusion. The present study has offered a practical contribution to existing knowledge of PNS ISO 15189:2013 accreditation compliance management by providing the medical laboratory with a practicable tool to determine the conformity status of Afinion 2 Analyzer maintainability in accordance with PNS ISO 15189:2013 conformance requirements, manufacturerandspecificrequirementsforaccreditation.

Original languageEnglish
Pages (from-to)72-91
Number of pages20
JournalActa Medica Philippina
Volume57
Issue number11
DOIs
StatePublished - 2023

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 7 - Affordable and Clean Energy
    SDG 7 Affordable and Clean Energy
  2. SDG 9 - Industry, Innovation, and Infrastructure
    SDG 9 Industry, Innovation, and Infrastructure
  3. SDG 12 - Responsible Consumption and Production
    SDG 12 Responsible Consumption and Production

Keywords

  • Afinion 2 Analyzer
  • ISO 15189:2012
  • management review
  • quality compliance
  • quality conformity
  • quality management

Fingerprint

Dive into the research topics of 'Conformity Evaluation of Afinion 2 Analyzer Maintainability: Compliance Practicality for Philippine National Standard PNS ISO 15189:2013 Accreditation'. Together they form a unique fingerprint.

Cite this