TY - GEN
T1 - Boxpect
T2 - 2020 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2020
AU - Ozsahin, Ilker
AU - Ozsahin, Dilber Uzun
AU - Makarov, Pavel A.
AU - Mok, Greta S.P.
N1 - Publisher Copyright:
© 2020 IEEE
PY - 2020
Y1 - 2020
N2 - Neurological diseases are currently one of the main causes of disability and mortality worldwide. Alzheimer's disease (AD) and Parkinson's disease (PD) are the two most common brain disorders with no cure. Neuroimaging based methods, such as magnetic resonance imaging (MRI), positron emission tomography (PET) and single photon emission computed tomography (SPECT) imaging, have been used to diagnose AD and PD. However, PET requires a cyclotron onsite for generally short-lived isotopes. In addition, PET and MRI are more expensive and less accessible. SPECT not only costs less than PET and MRI, but also has longer half-life isotopes available. The aim of this study is to evaluate a high sensitivity multi-pinhole brain SPECT system. The proposed system sensitivity was evaluated using Geant4 Application for Tomographic Emission. We first determined the design parameters by maximizing the sensitivity for a target resolution of 11.4 mm and field of view of 200 mm. The preliminary simulation results showed that a system sensitivity of 0.204% was achieved, which is very high compared to existing clinical brain SPECT systems. The improved sensitivity of the device can be traded for better spatial resolution, reduced injection dose or shortened acquisition time.
AB - Neurological diseases are currently one of the main causes of disability and mortality worldwide. Alzheimer's disease (AD) and Parkinson's disease (PD) are the two most common brain disorders with no cure. Neuroimaging based methods, such as magnetic resonance imaging (MRI), positron emission tomography (PET) and single photon emission computed tomography (SPECT) imaging, have been used to diagnose AD and PD. However, PET requires a cyclotron onsite for generally short-lived isotopes. In addition, PET and MRI are more expensive and less accessible. SPECT not only costs less than PET and MRI, but also has longer half-life isotopes available. The aim of this study is to evaluate a high sensitivity multi-pinhole brain SPECT system. The proposed system sensitivity was evaluated using Geant4 Application for Tomographic Emission. We first determined the design parameters by maximizing the sensitivity for a target resolution of 11.4 mm and field of view of 200 mm. The preliminary simulation results showed that a system sensitivity of 0.204% was achieved, which is very high compared to existing clinical brain SPECT systems. The improved sensitivity of the device can be traded for better spatial resolution, reduced injection dose or shortened acquisition time.
KW - Brain SPECT
KW - GATE
KW - Multi-pinhole collimator
UR - https://www.scopus.com/pages/publications/85124687993
U2 - 10.1109/NSS/MIC42677.2020.9507876
DO - 10.1109/NSS/MIC42677.2020.9507876
M3 - Conference contribution
AN - SCOPUS:85124687993
T3 - 2020 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2020
BT - 2020 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2020
PB - Institute of Electrical and Electronics Engineers Inc.
Y2 - 31 October 2020 through 7 November 2020
ER -