Skip to main navigation Skip to search Skip to main content

Amniotic membrane graft for persistent macular hole following retinal detachment repair in Knobloch syndrome

  • Cleveland Clinic Abu Dhabi
  • Cleveland Clinic Lerner College of Medicine of Case Western Reserve University

Research output: Contribution to journal › Article › peer-review

1 Scopus citations

Abstract

We report the case of a 7-year-old girl with Knobloch syndrome who presented with retinal detachment due to a macular hole, which was treated with vitrectomy and silicone oil tamponade. The macular hole persisted, and recurrent silicone oil emulsification required exchanges, with two subsequent vitrectomies. Finally, an amniotic membrane graft was used to seal the macular hole in an effort to avoid silicone oil dependence for retinal attachment. The macular hole was successfully closed, and the retina remained attached 6 months after surgery.

Original languageEnglish
Article number104017
JournalJournal of AAPOS
Volume28
Issue number6
DOIs
StatePublished - Dec 2024

Fingerprint

Dive into the research topics of 'Amniotic membrane graft for persistent macular hole following retinal detachment repair in Knobloch syndrome'. Together they form a unique fingerprint.

Cite this