Skip to main navigation Skip to search Skip to main content

3-Year Outcomes After Valve-in-Valve Transcatheter Aortic Valve Replacement for Degenerated Bioprostheses: The PARTNER 2 Registry

  • John G. Webb
  • , Dale J. Murdoch
  • , Maria C. Alu
  • , Anson Cheung
  • , Aaron Crowley
  • , Danny Dvir
  • , Howard C. Herrmann
  • , Susheel K. Kodali
  • , Jonathon Leipsic
  • , D. Craig Miller
  • , Philippe Pibarot
  • , Rakesh M. Suri
  • , David Wood
  • , Martin B. Leon
  • , Michael J. Mack
  • St Paul's Hospital
  • Columbia University
  • Cardiovascular Research Foundation
  • University of Washington
  • University of Pennsylvania
  • Stanford University
  • Université Laval
  • Baylor Scott & White Health

Research output: Contribution to journal › Article › peer-review

157 Scopus citations

Abstract

Background: Transcatheter aortic valve replacement (TAVR) for degenerated surgical bioprosthetic aortic valves is associated with favorable early outcomes. However, little is known about the durability and longer-term outcomes associated with this therapy. Objectives: The aim of this study was to examine late outcomes after valve-in-valve TAVR. Methods: Patients with symptomatic degeneration of surgical aortic bioprostheses at high risk (≥50% major morbidity or mortality) for reoperative surgery were prospectively enrolled in the multicenter PARTNER (Placement of Aortic Transcatheter Valves) 2 valve-in-valve and continued access registries. Three-year clinical and echocardiographic follow-up was obtained. Results: Valve-in-valve procedures were performed in 365 patients. The mean age was 78.9 ± 10.2 years, and the mean Society of Thoracic Surgeons score was 9.1 ± 4.7%. At 3 years, the overall Kaplan-Meier estimate of all-cause mortality was 32.7%. Aortic valve re-replacement was required in 1.9%. Mean transaortic gradient was 35.0 mm Hg at baseline, decreasing to 17.8 mm Hg at 30-day follow-up and 16.6 mm Hg at 3-year follow-up. Baseline effective orifice area was 0.93 cm2, increasing to 1.13 and 1.15 cm2 at 30 days and 3 years, respectively. Moderate to severe aortic regurgitation was reduced from 45.1% at pre-TAVR baseline to 2.5% at 3 years. Importantly, moderate or severe mitral and tricuspid regurgitation also decreased (33.7% vs. 8.6% [p < 0.0001] and 29.7% vs. 18.8% [p = 0.002], respectively). Baseline left ventricular ejection fraction was 50.7%, increasing to 54.7% at 3 years (p < 0.0001), while left ventricular mass index was 136.4 g/m2, decreasing to 109.1 g/m2 at 3 years (p < 0.0001). New York Heart Association functional class improved, with 90.4% in class III or IV at baseline and 14.1% at 3 years (p < 0.0001), and Kansas City Cardiomyopathy Questionnaire overall score increased (43.1 to 73.1; p < 0.0001). Conclusions: At 3-year follow-up, TAVR for bioprosthetic aortic valve failure was associated with favorable survival, sustained improved hemodynamic status, and excellent functional and quality-of-life outcomes.

Original languageEnglish
Pages (from-to)2647-2655
Number of pages9
JournalJournal of the American College of Cardiology
Volume73
Issue number21
DOIs
StatePublished - 4 Jun 2019

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Keywords

  • 6-min walk distance
  • aortic stenosis
  • mortality
  • registry
  • regurgitation

Fingerprint

Dive into the research topics of '3-Year Outcomes After Valve-in-Valve Transcatheter Aortic Valve Replacement for Degenerated Bioprostheses: The PARTNER 2 Registry'. Together they form a unique fingerprint.

Cite this