Project Details
Description
When applied according to manufacturer recommendations, short-pulse system may yield more temporary reduction in edema while infrared micropulse system may yield slightly better functional outcomes.
Layman's description
Purpose: To assess both anatomic and functional outcomes between short-pulse continuous wavelength and infrared micropulse lasers in the treatment of DME.
Materials and Methods: A prospective interventional study from tertiary care eye hospital - King Khaled Eye Specialist Hospital (Riyadh, Saudi Arabia). Patients with center-involving diabetic macular edema were treated with subthreshold laser therapy. Patients in the micropulse group were treated with the 810-nm diode micropulse scanning laser TxCell™ (IRIDEX Corporation, Mountain View, CA, USA). Laser was applied according to manufacturer recommendations for MicroPulseTM in a confluent mode (low intensity/high density) to the entire area of the macular edema. Patients in the short-pulse group were treated with grid pattern laser with 20ms pulse PASCAL laser 532nm (TopCon Medical Laser Systems, Tokyo, Japan) with EndPoint algorithm, which was either 30% or 50% of testing burn. Main outcome measures included best-corrected visual acuity (BCVA) and foveal thickness at baseline and the last follow-up visit.
Materials and Methods: A prospective interventional study from tertiary care eye hospital - King Khaled Eye Specialist Hospital (Riyadh, Saudi Arabia). Patients with center-involving diabetic macular edema were treated with subthreshold laser therapy. Patients in the micropulse group were treated with the 810-nm diode micropulse scanning laser TxCell™ (IRIDEX Corporation, Mountain View, CA, USA). Laser was applied according to manufacturer recommendations for MicroPulseTM in a confluent mode (low intensity/high density) to the entire area of the macular edema. Patients in the short-pulse group were treated with grid pattern laser with 20ms pulse PASCAL laser 532nm (TopCon Medical Laser Systems, Tokyo, Japan) with EndPoint algorithm, which was either 30% or 50% of testing burn. Main outcome measures included best-corrected visual acuity (BCVA) and foveal thickness at baseline and the last follow-up visit.
| Status | Finished |
|---|---|
| Effective start/end date | 1/01/15 → 1/01/17 |
Collaborative partners
- Moorfields Eye Hospital Centre Abu Dhabi (lead)
- King Khaled Eye Specialist Hospital
- University of Nebraska
- Abu Dhabi Health Services Company
Keywords
- Micropulse Laser
- Macular Degeneration
- Retinal Degeneration
- Retinal Diseases
- Eye Diseases
- Macular Edema
- Edema
Fingerprint
Explore the research topics touched on by this project. These labels are generated based on the underlying awards/grants. Together they form a unique fingerprint.